ANSWERS LEED-AP-BD-C REAL QUESTIONS | NEW LEED-AP-BD-C TEST VOUCHER

Answers LEED-AP-BD-C Real Questions | New LEED-AP-BD-C Test Voucher

Answers LEED-AP-BD-C Real Questions | New LEED-AP-BD-C Test Voucher

Blog Article

Tags: Answers LEED-AP-BD-C Real Questions, New LEED-AP-BD-C Test Voucher, LEED-AP-BD-C Trustworthy Pdf, LEED-AP-BD-C Passing Score Feedback, Online LEED-AP-BD-C Bootcamps

DOWNLOAD the newest SureTorrent LEED-AP-BD-C PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1jkXCJa-ajBjcTuCq4DohTkt298Z05ExL

There is an irreplaceable trend that an increasingly amount of clients are picking up LEED-AP-BD-C practice materials from tremendous practice materials in the market. There are unconquerable obstacles ahead of us if you get help from our LEED-AP-BD-C practice materials. So many exam candidates feel privileged to have our LEED-AP-BD-C practice materials. Your aspiring wishes such as promotion chance, or higher salaries or acceptance from classmates or managers and so on. And if you want to get all benefits like that, our LEED-AP-BD-C practice materials are your rudimentary steps to begin.

USGBC LEED-AP-BD-C Exam Syllabus Topics:

TopicDetails
Topic 1
  • Water Efficiency: This topic measures the skills of LEED Green Associates in optimizing water use in building projects. It explores strategies for reducing outdoor water use through efficient irrigation practices, including landscape water requirements and irrigation systems. It also covers using native and adaptive plant species to minimize irrigation demands.
Topic 2
  • Energy and Atmosphere: In this topic, LEED Green Associates focuses on building reuse, including historic building renovations. It covers material reuse strategies, enclosure materials, and permanently installed interior components into new designs.
Topic 3
  • Indoor Environmental Quality: This domain measures the skills of LEED Green Associates in creating healthy indoor environments. It emphasizes the importance of maintaining adequate ventilation levels through both natural and mechanical means. Additionally, candidates will be assessed on topics such as tobacco smoke control measures.
Topic 4
  • Integrative Strategies: It emphasizes the importance of an integrative process. The topic also covers their knowledge about the value of teamwork in developing integrative green strategies and how they can collaborate throughout different project phases.
Topic 5
  • LEED Process: This topic tests the skills of LEED Green Associates involved in green building initiatives. It focuses on various methods to achieve LEED goals, such as developing credit interpretation rulings and utilizing Regional Priority Credits to explore synergies within the LEED system.
Topic 6
  • Building Loads: This topic is focused on optimizing building performances through effective load management. It addresses design considerations such as building orientation and glazing selection while clarifying regional factors that influence these decisions.
Topic 7
  • Location and Transportation: This topic measures the skills of LEED Green Associates in sustainable development. It addresses critical factors in site selection, including development constraints and opportunities related to environmental considerations, and community connectivity concepts, such as walkability and street design, which are vital for promoting sustainable transportation options.

>> Answers LEED-AP-BD-C Real Questions <<

Updated USGBC Answers LEED-AP-BD-C Real Questions - LEED-AP-BD-C Free Download

The LEED AP Building Design + Construction (LEED AP BD+C) (LEED-AP-BD-C) exam dumps are real and updated LEED-AP-BD-C exam questions that are verified by subject matter experts. They work closely and check all LEED-AP-BD-C exam dumps one by one. They maintain and ensure the top standard of SureTorrent LEED-AP-BD-C Exam Questions all the time. The LEED-AP-BD-C practice test is being offered in three different formats. These LEED-AP-BD-C exam questions formats are PDF dumps files, web-based practice test software, and desktop practice test software.

USGBC LEED AP Building Design + Construction (LEED AP BD+C) Sample Questions (Q139-Q144):

NEW QUESTION # 139
Which of the following must be included in the Sustainable Sites Credit, Site Assessment?

  • A. Historic preservation plan to include neighboring properties
  • B. Proximity of vulnerable populations to major sources of air pollution
  • C. The surrounding density within a 1/4 mi. (0.40 km) radius of the project boundary
  • D. A targeted Brownfield remedy plan

Answer: B

Explanation:
The correct answer is C. Proximity of vulnerable populations to major sources of air pollution.
According to the LEED v4.1 Reference Guide for Building Design and Construction, the Site Assessment credit requires projects to conduct and document a site inventory and analysis that covers the following topics1:
* Topography
* Hydrology
* Climate
* Vegetation
* Soils
* Human use
* Human health effects
The human health effects topic includes identifying the proximity of vulnerable populations, such as children, elderly, or low-income residents, to major sources of air pollution, such as highways, power plants, or industrial facilities. This information can help the project team design strategies to minimize the exposure of occupants and visitors to harmful pollutants and improve the indoor and outdoor air quality of the project1.
The other options are not required for the Site Assessment credit, although they may be relevant for other credits or prerequisites. A targeted Brownfield remedy plan is required for the Brownfields Remediation credit, which applies to projects located on sites contaminated by past uses1. A historic preservation plan to include neighboring properties is not required for any LEED credit, although projects that involve historic buildings or districts must comply with local regulations and standards for preservation1. The surrounding density within a 1/4 mi. (0.40 km) radius of the project boundary is not required for the Site Assessment credit, but it is used to calculate the points for the Surrounding Density and Diverse Uses credit, which encourages projects to locate in areas with high levels of existing development and mixed land uses1.


NEW QUESTION # 140
In a large industrial or commercial building, which energy end uses are classified as systems composed of discrete pieces of equipment that can be metered together for the purposes of Energy and Atmosphere Credit, Advanced Energy Metering?

  • A. Electrical lighting system during peak use hours
  • B. Condenser water system with a cooling tower and condenser water pumps
  • C. HVAC air system for air conditioning
  • D. Water flow system used for public faucets and toilets

Answer: B

Explanation:
Explanation
A condenser water system with a cooling tower and condenser water pumps is classified as a system composed of discrete pieces of equipment that can be metered together for the purposes of Energy and Atmosphere Credit, Advanced Energy Metering. This is because the condenser water system is a single energy end use that serves a specific function and can be isolated from other systems1. HVAC air system, electrical lighting system, and water flow system are not considered as single energy end uses, but rather as multiple energy end uses that serve different functions and cannot be easily isolated2.
References:
*LEED v4 for Building Design and Construction, p. 415
*Advanced Energy Metering, p. 2


NEW QUESTION # 141
A project's total site area is 240,000 ft2 (22 297 m2) and the building footprint is 40,000 ft2 (3 716 m2). How much outdoor space and vegetated space must it provide to earn Sustainable Sites Credit, Open Space?

  • A. 60,000 ft2 (5 574 m2) of outdoor space of which 50,000 ft2 (4 645 m2) must be vegetated
  • B. 72,000 ft2 (6 689 m2) of outdoor space of which 18,000 ft2 (1 672 m2) must be vegetated
  • C. 72,000 ft2 (6 689 m2) of outdoor space of which 60,000 ft2 (5 574 m2) must be vegetated
  • D. 60,000 ft2 (5 574 m2) of outdoor space of which 15,000 ft2 (1 394 m2) must be vegetated

Answer: B

Explanation:
According to the LEED v4 Reference Guide for Building Design and Construction, the project must provide outdoor space that is at least 30% of the total site area (including the building footprint), of which at least 25% must be vegetated. In this case, the project must provide 0.3 x 240,000 ft2 = 72,000 ft2 (6 689 m2) of outdoor space, of which 0.25 x 72,000 ft2 = 18,000 ft2 (1 672 m2) must be vegetated. Therefore, option C is the correct answer. References: LEED v4 Reference Guide for Building Design and Construction, p. 5411


NEW QUESTION # 142
Which of the following strategies is allowed under Energy Atmosphere Credit, Renewable Energy Production, and will help a project achieve Energy Atmosphere Credit, Optimize Energy Performance?

  • A. Install a ground-source heat pump
  • B. Purchase Green-e certified Renewable Energy Certificates (RECs)
  • C. Purchase Green-e certified carbon offsets
  • D. Install an on-site photovoltaic array

Answer: D

Explanation:
Install an on-site photovoltaic array
Installing an on-site photovoltaic array is a direct method to produce renewable energy on the project site, which can be used to achieve points under the Energy Atmosphere Credit for Renewable Energy Production.
Additionally, it contributes to optimizing energy performance by generating clean electricity on-site and reducing the need for energy from non-renewable sources.


NEW QUESTION # 143
A new athletic facility contains a laundry room which is adjacent to the locker rooms. Which strategy will contribute toward the Interior Cross-Contamination Prevention strategy in Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies?

  • A. Install particle filters, with a MERV of 13 or higher or F7
  • B. Provide a ventilation system specifically for the laundry facility that has no recirculating air
  • C. Relocate the laundry facility to the basement
  • D. Naturally ventilate the laundry space per ASHRAE 62.1-2010

Answer: B

Explanation:
The strategy that will contribute toward the Interior Cross-Contamination Prevention strategy in Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies is to provide a ventilation system specifically for the laundry facility that has no recirculating air. This is because the laundry facility is a space where hazardous gases or chemicals may be present or used, such as detergents, bleach, or fabric softeners. According to the LEED v4 Reference Guide for Building Design and Construction, the project must "sufficiently exhaust each space where hazardous gases or chemicals may be present or used (e.g., garages, housekeeping and laundry areas, copying and printing rooms), using the exhaust rates determined in EQ Prerequisite Minimum Indoor Air Quality Performance or a minimum of 0.50 cfm per square foot (2.54 l/s per square meter), to create negative pressure with respect to adjacent spaces when the doors to the room are closed. For each of these spaces, provide self-closing doors and deck-to-deck partitions or a hard-lid ceiling."1 Therefore, option D is the correct answer. The other options will not prevent cross-contamination from the laundry facility to the locker rooms. Relocating the laundry facility to the basement (option A) may reduce the exposure of the occupants to the laundry chemicals, but it will not eliminate the possibility of cross-contamination to other spaces in the basement. Naturally ventilating the laundry space per ASHRAE 62.1-2010 (option B) may not provide sufficient exhaust to create negative pressure and prevent cross-contamination, especially if the outdoor air quality is poor or the natural ventilation is not well designed. Installing particle filters, with a MERV of 13 or higher or F7 (option C) may improve the air quality in the laundry space, but it will not prevent the hazardous gases or chemicals from escaping to the adjacent spaces through the ventilation system or the gaps in the doors or ceiling. Reference: LEED v4 Reference Guide for Building Design and Construction, p. 6881; ASHRAE Standard 62.1-2010, Section 6.2.52


NEW QUESTION # 144
......

The passing rate of our LEED-AP-BD-C exam materials are very high and about 99% and so usually the client will pass the exam successfully. But in case the client fails in the exam unfortunately we will refund the client immediately in full at one time. The refund procedures are very simple if you provide the LEED-AP-BD-C exam proof of the failure marks we will refund you immediately. If any questions or doubts exist, the client can contact our online customer service or send mails to contact us and we will solve them as quickly as we can. We always want to let the clients be satisfied and provide the best LEED-AP-BD-C Test Torrent and won’t waste their money and energy.

New LEED-AP-BD-C Test Voucher: https://www.suretorrent.com/LEED-AP-BD-C-exam-guide-torrent.html

DOWNLOAD the newest SureTorrent LEED-AP-BD-C PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1jkXCJa-ajBjcTuCq4DohTkt298Z05ExL

Report this page